AC Resonant Test System for Generator
AC Resonant Test System for Generator can be used by adjusting inductance of the reactor, or adjusting the work way of resonant frequency of the system to achieve resonance.You can also use both two methods to achieve resonance.In the voltage boosting process, if the resonant point deviate,you can find it exactly by the way of fine tuning frequency,which ensure a high Q value and reduce power capacity and volume weight of test equipment.
Product Features:
1. Smaller size,lighter weight compared with same voltage level,same capacity generator AC withstand voltage test equipments.Single equipment is no more than 60kg,easy to move;
2. Advanced principle of whole set device and new frequency&inductance modulation technology, strictly ensure generator power frequency withstand voltage test requirements. Wide application range;
3. Equipped with 20Hz-300Hz variable control source. Good protection and output waveform,high stability.Multiple working mode,easy to operate;
4. Power supply of 220V or 380V, convenient for on-site power connection;
5. Max.Q point can be found exactly by the mode of first inductance modulation and later frequency modulation,to avoid resonance deviation because of voltage boosting;
6. Flexible configuration and strong extension. Meet all capacitive test object testing requirements in power system;
7. 2 Testing Mode: Power frequency test mode or Variable frequency test mode;
8. Multi-function and cost-effective.
Model Specification(can be customized):
Model | Scope of application(Generators with output voltage≤20KV,50Hz±2Hz) | |||||
FA Power | Regulator | Resonant Reactor
(Dry Type) |
Exciting Transformer
(Dry Type) |
Capacitive
Divider |
Scope of Application | |
GP-D-200/25 | 30kW | 30kVA (electric) | 200kVA/25kV 1 set | 30kVA ((Dry Type) | 30kV | Hydroelectric generator |
0.4~1.0μF | ||||||
(10kV/40MW) | ||||||
GP-D-300/50 | 60kW | 60kVA (electric) | 300kVA/50kV 1 set | 60kVA (Oil Immersed) | 50kV | thermoelectric generator |
0.27~0.33μF | ||||||
(20kV/300MW) | ||||||
GP-D-600/50 | 60kW | 60kVA (electric) | 200kVA/50kV 1 set
400kVA/50kV 1 set |
60kVA (Oil Immersed) | 50kV | thermoelectric generator |
0.113~0.45μF | ||||||
(20kV/600MW) | ||||||
GP-D-1200/50 | 120kW | 120kVA (induction) | 200kVA/50kV 2 set
800kVA/50kV 1 set |
120kVA (Oil Immersed) | 50kV | Hydroelectric generator |
0.6~1.8μF | ||||||
(20kV/250MW) | ||||||
GP-D-2750/55 | 300kW | 300kVA (induction) | 750kVA/55kV 2 set
1250kVA/55kV 1 set |
300kVA (Oil Immersed) | 60kV | Hydroelectric generator |
1.6~3.3μF | ||||||
(20kV/770MW) |
Also called as:
Generator Resonance Test System, Generator Resonance Test Equipment,